Siemens Burner Controllers LME39 Series are gas burner control units designed for the startup and supervision of small to medium-capacity, 1- or 2-stage gas burners in intermittent operation. They support flame monitoring via an ionization probe or a QRA UV flame detector with an AGQ3 ancillary unit, depending on the configuration. Key features include digital program sequencing, air pressure supervision, undervoltage detection, multicolor LED diagnostics, remote reset, and adjustable operating parameters. Suitable for industrial boilers and gas-fired heating applications.

Product Details

Siemens Burner Controllers LME39 Series

Siemens Burner Controllers LME39 Series

Siemens LME39 Series are automatic gas burner control units designed for the startup and supervision of small to medium-capacity 1- or 2-stage gas burners, with or without a fan, operating in intermittent mode.

The LME39 Series uses digital signal processing to provide accurate burner program sequencing, including startup, ignition, flame supervision, and controlled shutdown. Integrated monitoring functions help detect abnormal operating conditions and support safe burner operation.

Key Features

  • Designed for 1- or 2-stage gas burners
  • Flame supervision using an ionization probe or QRA UV detector with AGQ3 ancillary unit, depending on configuration
  • Accurate burner sequencing through digital signal processing
  • Integrated undervoltage detection
  • Air pressure supervision during startup and operation, depending on parameterization
  • Multicolor LED indication for operating status and fault diagnostics
  • Electrical remote lockout reset capability
  • Configurable restart limitation
  • Controlled intermittent operation after a maximum of 24 hours of continuous operation
  • Parameterization and diagnostics using AZL2 or ACS410 with compatible interface accessories

Available Models

  • LME39.100C1 – AC 120 V
  • LME39.100C2 – AC 230 V
  • LME39.400C1 – AC 120 V
  • LME39.400C2 – AC 230 V

Each model has specific program sequences and timing requirements. The correct model and parameter settings must be selected according to the burner application.

Typical Applications

  • Industrial gas-fired boiler systems
  • Gas-fired heating equipment
  • Single-stage and two-stage gas burners
  • Burner systems requiring flame supervision
  • Intermittent gas combustion applications

Selection Guidelines

Before selecting an LME39 burner controller, verify the supply voltage, model designation, flame detector type, required program sequence, and operating parameters. Installation, commissioning, and parameter adjustments should be performed by qualified personnel in accordance with Siemens technical documentation.

Siemens Burner Controllers LME39 Series

Technical Specifications

Siemens LME39 Series Technical Specifications

Brand Siemens
Series LME39 Series
Product Type Gas Burner Controls
Burner Type 1-/2-Stage Gas Burners
Operating Mode Intermittent Operation
Supply Voltage AC 120 V +10%/-15% (C1 models)
AC 230 V +10%/-15% (C2 models)
Supply Frequency 50–60 Hz
Power Consumption 12 VA
Flame Detection Ionization Probe or QRA UV Detector with AGQ3 ancillary unit (UV supervision with AC 230 V models only)
Flame Failure Response Time Max. 1 second
Operating Temperature -20°C to +60°C
Relative Humidity Less than 95% RH
Degree of Protection IP40 with appropriate installation (IP10 if the RJ11 jack is uncovered)
Weight Approx. 160 g
External Primary Fuse Max. T6.3H250V
Installation Altitude Max. 2,000 m above sea level
Applicable Standards DIN EN 298, DIN EN 13611, DIN EN 60730-2-5

Model Variants and Program Timing

Model Voltage Safety Time (TSA) Prepurge / Purge
LME39.100C1 AC 120 V Max. 3 s t1: Min. 30 s
LME39.100C2 AC 230 V Max. 3 s t1: Min. 30 s
LME39.400C1 AC 120 V Max. 5 s t1': Min. 14.5 s
LME39.400C2 AC 230 V Max. 5 s t1': Min. 14.5 s

Note: Program timing values are based on the manufacturer's type summary. Actual operating values depend on the model and parameter configuration. The AGK11.6 plug-in base and flame detector are ordered separately.

Dimensions

Documents & Downloads

SIEMENS_GAS_BURNER_CONTROLS_LME39-7106_2022-boonyiumPDF
Download

Frequently Asked Questions

For product questions, please contact our engineering team.

Need expert assistance?

Our engineers can help choose suitable equipment.

Contact us

Request a Quotation / Product Inquiry

Send your product inquiry and our team will contact you.